Nitrogen concentration is high precision temperature control instrument by microcomputer processing and PID control method are combined to form, its working principle is to fast, continuous and controllable nitrogen blowing to the heating surface of the sample, according to the concentration of solvent evaporation rate and the boiling point, set the heating temperature, concentration of a large number of samples to achieve fast. The instrument adopts aluminum plate heating module, which has good heat transfer and uniform heat transfer. Nitrogen is blown to the surface of the sample to achieve the anaerobic concentration of liquid samples. Blowpipe is independent of each other, and will not cause cross contamination. Each gas channel on the gas distribution assembly can be combined or used alone. The system has the advantages of high temperature control precision, wide temperature control range, temperature digital display and temperature calibration. The product is beautiful and easy to use, safe and reliable to use.
Product features
> Gas needles are independent of each other and do not cause cross contamination;
> The flow rate can be adjusted individually;
> Each channel can be combined or used alone;
> Each gas needle flow control valve and the module hole corresponding to the vertical adjustment intuitive and convenient;
> The system has the advantages of high temperature control precision, wide temperature control range and convenient temperature calibration;
> Lifting assembly with independent positioning safety plug, long-term use safety;
Application area
> Analysis of pesticide residues: such as vegetables, fruits and grains, plant tissue
> Environmental analysis: drinking water, groundwater and contaminated water samples
> Biological analysis: sample preparation in hormone analysis, liquid phase, gas phase and mass spectrometric analysis
> Food beverages such as milk, wine, beer, etc.
> Pharmaceutical testing: such as Chinese medicine, drug screening
Technical parameter
Nitrogen concentration JN300-3(RT+5°C-150°C)
Model |
JN300-3 |
Temperature range |
RT+5°C-150°C |
Timing range |
99h59min |
Control accuracy |
≤ ±0.5 °C |
Display accuracy |
0.1 °C |
Temperature uniformity (100 °C) |
≤ ±0.5 °C |
Temperature uniformity (150 °C) |
≤ ±1 °C |
Heating time (40°C -150°C) |
≤30 min |
Lift distance |
200mm |
Maximum pressure |
0.1Mpa |
Maximum airflow |
15L/min |
Needle length |
150mm |
Module number |
1個 |
Outline dimension |
230x225x470mm |
Instrument weight |
6kg |
Heating power |
200W |
Power |
220V 50Hz(Special voltage can be informed in advance to provide foreign voltage) |
Nitrogen concentration module
Module type |
Aperture |
Tube number |
Module type |
Aperture |
Tube number |
A |
Φ10mm |
12 |
E |
Φ16mm |
12 |
B |
Φ12mm |
12 |
F |
Φ19mm |
12 |
C |
Φ13mm |
12 |
G |
Φ20mm |
12 |
D |
Φ15mm |
12 |
|
|
|
Note: the gas flow of nitrogen concentration can control each of the gas needle, no flow control valve can realize the single and multiple needle and gas flow control instrument; according to the host configuration module, JN300-3 module 1, module module can be selected in the area, a standard module for A-G modules need an extra charge. The former can contact customer service, custom modules required period, please confirm in advance!
More information about the nitrogen dryer / nitrogen purging device,Can access www.jiminuo.com /www.098599.com;